Passa al contenuto

SIEMENS 3RA2110-1BH15-1AP0 LOAD FEEDER DIRECT STARTER S00

(0 recensione)
198,00 € 198,00 € (Imposte escluse)

  • Width
  • Depth
  • Degree of protection (IP)
  • Height
  • Degree of protection (NEMA)
  • Rated operation power at AC-3, 400 V
  • Number of auxiliary contacts as normally open contact
  • Number of auxiliary contacts as normally closed contact
  • Type of electrical connection of main circuit
  • Voltage type for actuating
  • With transformer
  • Number of command positions
  • Suitable for emergency stop
  • Rated operation current Ie
  • Number of indicator lights
  • Overload release current setting
  • Supporting protocol for LON
  • Supporting protocol for TCP/IP
  • Supporting protocol for ASI
  • Supporting protocol for PROFIBUS
  • Supporting protocol for CAN
  • Supporting protocol for INTERBUS
  • Supporting protocol for MODBUS
  • Supporting protocol for Data-Highway
  • Supporting protocol for DeviceNet
  • Supporting protocol for SUCONET
  • Supporting protocol for other bus systems
  • External reset possible
  • Rail mounting possible
  • Rated control supply voltage Us at AC 50HZ
  • Rated control supply voltage Us at AC 60HZ
  • Rated control supply voltage Us at DC
  • Supporting protocol for SERCOS
  • Supporting protocol for INTERBUS-Safety
  • Release class
  • With short-circuit release
  • With fuse
  • Type of electrical connection for auxiliary- and control current circuit
  • Supporting protocol for AS-Interface Safety at Work
  • Supporting protocol for DeviceNet Safety
  • Supporting protocol for EtherNet/IP
  • Supporting protocol for Foundation Fieldbus
  • Supporting protocol for PROFINET CBA
  • Supporting protocol for PROFINET IO
  • Supporting protocol for PROFIsafe
  • Supporting protocol for SafetyBUS p
  • Kind of motor starter
  • Rated operation power at AC-3, 230 V, 3-phase
  • Rated power, 460 V, 60 Hz, 3-phase
  • Rated power, 575 V, 60 Hz, 3-phase
  • Rated operation current at AC-3, 400 V
  • Ambient temperature, upper operating limit
  • Temperature compensated overload protection
  • Rated conditional short-circuit current, type 2, 400 V
  • Rated conditional short-circuit current, type 2, 230 V
  • Rated conditional short-circuit current, type 1, 480 Y/277 V
  • Rated conditional short-circuit current, type 1, 600 Y/347 V
  • Coordination class according to IEC 60947-4-3
Termini e condizioni
Garanzia di rimborso di 30 giorni
Spedizione: 2-3 giorni lavorativi

Il contenuto verrà condiviso in tutte le pagine prodotto.

Width: 45.000
Depth: 155.000
Degree of protection (IP): IP20
Height: 260.000
Degree of protection (NEMA): Other
Rated operation power at AC-3, 400 V: 0.750
Number of auxiliary contacts as normally open contact: -
Number of auxiliary contacts as normally closed contact: -
Type of electrical connection of main circuit: Spring clamp connection
Voltage type for actuating: AC
With transformer: false
Number of command positions: 1.000
Suitable for emergency stop: true
Rated operation current Ie: -
Number of indicator lights: 0.000
Overload release current setting: -
Supporting protocol for LON: false
Supporting protocol for TCP/IP: false
Supporting protocol for ASI: false
Supporting protocol for PROFIBUS: false
Supporting protocol for CAN: false
Supporting protocol for INTERBUS: false
Supporting protocol for MODBUS: false
Supporting protocol for Data-Highway: false
Supporting protocol for DeviceNet: false
Supporting protocol for SUCONET: false
Supporting protocol for other bus systems: false
External reset possible: false
Rail mounting possible: false
Rated control supply voltage Us at AC 50HZ: 230.000
Rated control supply voltage Us at AC 60HZ: 230.000
Rated control supply voltage Us at DC: -
Supporting protocol for SERCOS: false
Supporting protocol for INTERBUS-Safety: false
Release class: CLASS 10
With short-circuit release: true
With fuse: false
Type of electrical connection for auxiliary- and control current circuit: Spring clamp connection
Supporting protocol for AS-Interface Safety at Work: false
Supporting protocol for DeviceNet Safety: false
Supporting protocol for EtherNet/IP: false
Supporting protocol for Foundation Fieldbus: false
Supporting protocol for PROFINET CBA: false
Supporting protocol for PROFINET IO: false
Supporting protocol for PROFIsafe: false
Supporting protocol for SafetyBUS p: false
Kind of motor starter: -
Rated operation power at AC-3, 230 V, 3-phase: -
Rated power, 460 V, 60 Hz, 3-phase: -
Rated power, 575 V, 60 Hz, 3-phase: -
Rated operation current at AC-3, 400 V: -
Ambient temperature, upper operating limit: -
Temperature compensated overload protection: true
Rated conditional short-circuit current, type 2, 400 V: -
Rated conditional short-circuit current, type 2, 230 V: -
Rated conditional short-circuit current, type 1, 480 Y/277 V: -
Rated conditional short-circuit current, type 1, 600 Y/347 V: -
Coordination class according to IEC 60947-4-3: -

Our latest content

Check out what's new in our company !

Your Dynamic Snippet will be displayed here... This message is displayed because you did not provide both a filter and a template to use.